FastECU NextGen · reverse engineering

Subaru TCU
ROM Definitions

Every calibration map currently exposed in the transmission control unit (TCU) ROM definitions used by FastECU NextGen — one file per ROM ID, each purchasable individually with permanent download access, including future updates. ECU definitions are on the ECU page.

Every definition is published in four formats — EcuFlash Metric (bar / °C / km/h), EcuFlash Standard (psi / °F / mph), and the matching RomRaider Metric / RomRaider Standard pair — so it drops straight into whichever tuning software you already use.

Definition not found on the list?

ROM definitions

9 ROM files
02EB2WB0NEWWIPSubaru TribecaEDM 2009 · 5EAT · SH705845 maps
Miscellaneous - Sensor Scalings1 map
MapShape / size
ATF Temperature Sensor Scaling16 cells / 32 B
Transmission - Line Pressure12 maps
MapShape / size
Line Pressure Minimum (ATF Temp)7 cells / 14 B
Line Pressure Base (1st)8x8 cells / 128 B
Line Pressure Base (2nd)8x8 cells / 128 B
Line Pressure Base (3rd)8x8 cells / 128 B
Line Pressure Base (4th)8x8 cells / 128 B
Line Pressure Base (5th)8x8 cells / 128 B
Line Pressure Base (Reverse)8x8 cells / 128 B
Line Pressure Minimum (Lock-up Pressure) A16 cells / 32 B
Line Pressure Minimum (Lock-up Pressure) B16 cells / 32 B
Line Pressure Solenoid Current9x9 cells / 162 B
Line Pressure Solenoid Current (Reverse and Alternate Gears)9x9 cells / 162 B
Line Pressure Solenoid Current (N-R Engagement)9x9 cells / 162 B
Transmission - Shift Schedule14 maps
MapShape / size
Shift Schedule Upshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Upshift Maximum5 cells / 10 B
Shift Schedule Upshift Minimum5 cells / 10 B
Shift Schedule Downshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Downshift Maximum5 cells / 10 B
Shift Schedule Downshift Minimum5 cells / 10 B
Transmission - Shift Control5 maps
MapShape / size
I/C Solenoid Current17x8 cells / 272 B
H and LR/C Solenoid Current17x8 cells / 272 B
D/C Solenoid Current17x8 cells / 272 B
F/B Solenoid Current17x8 cells / 272 B
Fwd/B Solenoid Current17x8 cells / 272 B
Transmission - Lock-up13 maps
MapShape / size
Lock-up Engage (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Engage (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Engage (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Engage (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Engage (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Release (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Release (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Release (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Release (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Release (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Coast Minimum Speed (Pattern 2 Normal)5 cells / 10 B
Lock-up Coast Minimum Speed (Pattern 3 Manual Gate)5 cells / 10 B
Lock-up Solenoid Current16x6 cells / 192 B
08FB2WA0NEWWIPSubaru Tribeca -USDM 2014 · 5EAT · SH705846 maps
Miscellaneous - Sensor Scalings1 map
MapShape / size
ATF Temperature Sensor Scaling16 cells / 32 B
Transmission - Line Pressure12 maps
MapShape / size
Line Pressure Minimum (ATF Temp)7 cells / 14 B
Line Pressure Base (1st)8x8 cells / 128 B
Line Pressure Base (2nd)8x8 cells / 128 B
Line Pressure Base (3rd)8x8 cells / 128 B
Line Pressure Base (4th)8x8 cells / 128 B
Line Pressure Base (5th)8x8 cells / 128 B
Line Pressure Base (Reverse)8x8 cells / 128 B
Line Pressure Minimum (Lock-up Pressure) A16 cells / 32 B
Line Pressure Minimum (Lock-up Pressure) B16 cells / 32 B
Line Pressure Solenoid Current9x9 cells / 162 B
Line Pressure Solenoid Current (Reverse and Alternate Gears)9x9 cells / 162 B
Line Pressure Solenoid Current (N-R Engagement)9x9 cells / 162 B
Transmission - Shift Schedule15 maps
MapShape / size
Shift Schedule Upshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Upshift Maximum5 cells / 10 B
Shift Schedule Upshift Minimum5 cells / 10 B
Shift Schedule Downshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Downshift Maximum5 cells / 10 B
Shift Schedule Downshift Minimum5 cells / 10 B
Shift Schedule Maximum Reduction (ATF Temp)7 cells / 14 B
Transmission - Shift Control5 maps
MapShape / size
I/C Solenoid Current17x8 cells / 272 B
H and LR/C Solenoid Current17x8 cells / 272 B
D/C Solenoid Current17x8 cells / 272 B
F/B Solenoid Current17x8 cells / 272 B
Fwd/B Solenoid Current17x8 cells / 272 B
Transmission - Lock-up13 maps
MapShape / size
Lock-up Engage (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Engage (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Engage (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Engage (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Engage (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Release (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Release (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Release (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Release (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Release (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Coast Minimum Speed (Pattern 2 Normal)5 cells / 10 B
Lock-up Coast Minimum Speed (Pattern 3 Manual Gate)5 cells / 10 B
Lock-up Solenoid Current16x6 cells / 192 B
25D12WB1NEWWIPSubaru Legacy -JDM 2008 · 5EAT · SH705845 maps
Miscellaneous - Sensor Scalings1 map
MapShape / size
ATF Temperature Sensor Scaling16 cells / 32 B
Transmission - Line Pressure12 maps
MapShape / size
Line Pressure Minimum (ATF Temp)7 cells / 14 B
Line Pressure Base (1st)8x8 cells / 128 B
Line Pressure Base (2nd)8x8 cells / 128 B
Line Pressure Base (3rd)8x8 cells / 128 B
Line Pressure Base (4th)8x8 cells / 128 B
Line Pressure Base (5th)8x8 cells / 128 B
Line Pressure Base (Reverse)8x8 cells / 128 B
Line Pressure Minimum (Lock-up Pressure) A16 cells / 32 B
Line Pressure Minimum (Lock-up Pressure) B16 cells / 32 B
Line Pressure Solenoid Current9x9 cells / 162 B
Line Pressure Solenoid Current (Reverse and Alternate Gears)9x9 cells / 162 B
Line Pressure Solenoid Current (N-R Engagement)9x9 cells / 162 B
Transmission - Shift Schedule14 maps
MapShape / size
Shift Schedule Upshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Upshift Maximum5 cells / 10 B
Shift Schedule Upshift Minimum5 cells / 10 B
Shift Schedule Downshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Downshift Maximum5 cells / 10 B
Shift Schedule Downshift Minimum5 cells / 10 B
Transmission - Shift Control5 maps
MapShape / size
I/C Solenoid Current17x8 cells / 272 B
H and LR/C Solenoid Current17x8 cells / 272 B
D/C Solenoid Current17x8 cells / 272 B
F/B Solenoid Current17x8 cells / 272 B
Fwd/B Solenoid Current17x8 cells / 272 B
Transmission - Lock-up13 maps
MapShape / size
Lock-up Engage (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Engage (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Engage (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Engage (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Engage (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Release (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Release (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Release (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Release (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Release (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Coast Minimum Speed (Pattern 2 Normal)5 cells / 10 B
Lock-up Coast Minimum Speed (Pattern 3 Manual Gate)5 cells / 10 B
Lock-up Solenoid Current16x6 cells / 192 B
25D1AWS1NEWWIPSubaru Legacy STiJDM - · 5EAT · SH705845 maps
Miscellaneous - Sensor Scalings1 map
MapShape / size
ATF Temperature Sensor Scaling16 cells / 32 B
Transmission - Line Pressure12 maps
MapShape / size
Line Pressure Minimum (ATF Temp)7 cells / 14 B
Line Pressure Base (1st)8x8 cells / 128 B
Line Pressure Base (2nd)8x8 cells / 128 B
Line Pressure Base (3rd)8x8 cells / 128 B
Line Pressure Base (4th)8x8 cells / 128 B
Line Pressure Base (5th)8x8 cells / 128 B
Line Pressure Base (Reverse)8x8 cells / 128 B
Line Pressure Minimum (Lock-up Pressure) A16 cells / 32 B
Line Pressure Minimum (Lock-up Pressure) B16 cells / 32 B
Line Pressure Solenoid Current9x9 cells / 162 B
Line Pressure Solenoid Current (Reverse and Alternate Gears)9x9 cells / 162 B
Line Pressure Solenoid Current (N-R Engagement)9x9 cells / 162 B
Transmission - Shift Schedule14 maps
MapShape / size
Shift Schedule Upshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Upshift Maximum5 cells / 10 B
Shift Schedule Upshift Minimum5 cells / 10 B
Shift Schedule Downshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Downshift Maximum5 cells / 10 B
Shift Schedule Downshift Minimum5 cells / 10 B
Transmission - Shift Control5 maps
MapShape / size
I/C Solenoid Current17x8 cells / 272 B
H and LR/C Solenoid Current17x8 cells / 272 B
D/C Solenoid Current17x8 cells / 272 B
F/B Solenoid Current17x8 cells / 272 B
Fwd/B Solenoid Current17x8 cells / 272 B
Transmission - Lock-up13 maps
MapShape / size
Lock-up Engage (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Engage (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Engage (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Engage (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Engage (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Release (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Release (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Release (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Release (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Release (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Coast Minimum Speed (Pattern 2 Normal)5 cells / 10 B
Lock-up Coast Minimum Speed (Pattern 3 Manual Gate)5 cells / 10 B
Lock-up Solenoid Current16x6 cells / 192 B
26DE2OB0NEWWIPSubaru Legacy -JDM 2008 · 5EAT · SH705845 maps
Miscellaneous - Sensor Scalings1 map
MapShape / size
ATF Temperature Sensor Scaling16 cells / 32 B
Transmission - Line Pressure12 maps
MapShape / size
Line Pressure Minimum (ATF Temp)7 cells / 14 B
Line Pressure Base (1st)8x8 cells / 128 B
Line Pressure Base (2nd)8x8 cells / 128 B
Line Pressure Base (3rd)8x8 cells / 128 B
Line Pressure Base (4th)8x8 cells / 128 B
Line Pressure Base (5th)8x8 cells / 128 B
Line Pressure Base (Reverse)8x8 cells / 128 B
Line Pressure Minimum (Lock-up Pressure) A16 cells / 32 B
Line Pressure Minimum (Lock-up Pressure) B16 cells / 32 B
Line Pressure Solenoid Current9x9 cells / 162 B
Line Pressure Solenoid Current (Reverse and Alternate Gears)9x9 cells / 162 B
Line Pressure Solenoid Current (N-R Engagement)9x9 cells / 162 B
Transmission - Shift Schedule14 maps
MapShape / size
Shift Schedule Upshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Upshift Maximum5 cells / 10 B
Shift Schedule Upshift Minimum5 cells / 10 B
Shift Schedule Downshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Downshift Maximum5 cells / 10 B
Shift Schedule Downshift Minimum5 cells / 10 B
Transmission - Shift Control5 maps
MapShape / size
I/C Solenoid Current17x8 cells / 272 B
H and LR/C Solenoid Current17x8 cells / 272 B
D/C Solenoid Current17x8 cells / 272 B
F/B Solenoid Current17x8 cells / 272 B
Fwd/B Solenoid Current17x8 cells / 272 B
Transmission - Lock-up13 maps
MapShape / size
Lock-up Engage (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Engage (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Engage (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Engage (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Engage (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Release (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Release (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Release (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Release (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Release (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Coast Minimum Speed (Pattern 2 Normal)5 cells / 10 B
Lock-up Coast Minimum Speed (Pattern 3 Manual Gate)5 cells / 10 B
Lock-up Solenoid Current16x6 cells / 192 B
EZAE2WB1NEWWIPSubaru Legacy GTEDM 2010 · 5EAT · SH705846 maps
Miscellaneous - Sensor Scalings1 map
MapShape / size
ATF Temperature Sensor Scaling16 cells / 32 B
Transmission - Line Pressure12 maps
MapShape / size
Line Pressure Minimum (ATF Temp)7 cells / 14 B
Line Pressure Base (1st)8x8 cells / 128 B
Line Pressure Base (2nd)8x8 cells / 128 B
Line Pressure Base (3rd)8x8 cells / 128 B
Line Pressure Base (4th)8x8 cells / 128 B
Line Pressure Base (5th)8x8 cells / 128 B
Line Pressure Base (Reverse)8x8 cells / 128 B
Line Pressure Minimum (Lock-up Pressure) A16 cells / 32 B
Line Pressure Minimum (Lock-up Pressure) B16 cells / 32 B
Line Pressure Solenoid Current9x9 cells / 162 B
Line Pressure Solenoid Current (Reverse and Alternate Gears)9x9 cells / 162 B
Line Pressure Solenoid Current (N-R Engagement)9x9 cells / 162 B
Transmission - Shift Schedule15 maps
MapShape / size
Shift Schedule Upshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Upshift Maximum5 cells / 10 B
Shift Schedule Upshift Minimum5 cells / 10 B
Shift Schedule Downshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Downshift Maximum5 cells / 10 B
Shift Schedule Downshift Minimum5 cells / 10 B
Shift Schedule Maximum Reduction (ATF Temp)7 cells / 14 B
Transmission - Shift Control5 maps
MapShape / size
I/C Solenoid Current17x8 cells / 272 B
H and LR/C Solenoid Current17x8 cells / 272 B
D/C Solenoid Current17x8 cells / 272 B
F/B Solenoid Current17x8 cells / 272 B
Fwd/B Solenoid Current17x8 cells / 272 B
Transmission - Lock-up13 maps
MapShape / size
Lock-up Engage (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Engage (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Engage (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Engage (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Engage (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Release (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Release (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Release (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Release (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Release (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Coast Minimum Speed (Pattern 2 Normal)5 cells / 10 B
Lock-up Coast Minimum Speed (Pattern 3 Manual Gate)5 cells / 10 B
Lock-up Solenoid Current16x6 cells / 192 B
PDDE2WA0NEWWIPSubaru Forester SH9 STiJDM 2010 · 5EAT · SH705846 maps
Miscellaneous - Sensor Scalings1 map
MapShape / size
ATF Temperature Sensor Scaling16 cells / 32 B
Transmission - Line Pressure12 maps
MapShape / size
Line Pressure Minimum (ATF Temp)7 cells / 14 B
Line Pressure Base (1st)8x8 cells / 128 B
Line Pressure Base (2nd)8x8 cells / 128 B
Line Pressure Base (3rd)8x8 cells / 128 B
Line Pressure Base (4th)8x8 cells / 128 B
Line Pressure Base (5th)8x8 cells / 128 B
Line Pressure Base (Reverse)8x8 cells / 128 B
Line Pressure Minimum (Lock-up Pressure) A16 cells / 32 B
Line Pressure Minimum (Lock-up Pressure) B16 cells / 32 B
Line Pressure Solenoid Current9x9 cells / 162 B
Line Pressure Solenoid Current (Reverse and Alternate Gears)9x9 cells / 162 B
Line Pressure Solenoid Current (N-R Engagement)9x9 cells / 162 B
Transmission - Shift Schedule15 maps
MapShape / size
Shift Schedule Upshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Upshift Maximum5 cells / 10 B
Shift Schedule Upshift Minimum5 cells / 10 B
Shift Schedule Downshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Downshift Maximum5 cells / 10 B
Shift Schedule Downshift Minimum5 cells / 10 B
Shift Schedule Maximum Reduction (ATF Temp)7 cells / 14 B
Transmission - Shift Control5 maps
MapShape / size
I/C Solenoid Current17x8 cells / 272 B
H and LR/C Solenoid Current17x8 cells / 272 B
D/C Solenoid Current17x8 cells / 272 B
F/B Solenoid Current17x8 cells / 272 B
Fwd/B Solenoid Current17x8 cells / 272 B
Transmission - Lock-up13 maps
MapShape / size
Lock-up Engage (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Engage (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Engage (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Engage (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Engage (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Release (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Release (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Release (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Release (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Release (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Coast Minimum Speed (Pattern 2 Normal)5 cells / 10 B
Lock-up Coast Minimum Speed (Pattern 3 Manual Gate)5 cells / 10 B
Lock-up Solenoid Current16x6 cells / 192 B
WQDE2WB1NEWWIPSubaru Impreza STiJDM 2011 · 5EAT · SH705846 maps
Miscellaneous - Sensor Scalings1 map
MapShape / size
ATF Temperature Sensor Scaling16 cells / 32 B
Transmission - Line Pressure12 maps
MapShape / size
Line Pressure Minimum (ATF Temp)7 cells / 14 B
Line Pressure Base (1st)8x8 cells / 128 B
Line Pressure Base (2nd)8x8 cells / 128 B
Line Pressure Base (3rd)8x8 cells / 128 B
Line Pressure Base (4th)8x8 cells / 128 B
Line Pressure Base (5th)8x8 cells / 128 B
Line Pressure Base (Reverse)8x8 cells / 128 B
Line Pressure Minimum (Lock-up Pressure) A16 cells / 32 B
Line Pressure Minimum (Lock-up Pressure) B16 cells / 32 B
Line Pressure Solenoid Current9x9 cells / 162 B
Line Pressure Solenoid Current (Reverse and Alternate Gears)9x9 cells / 162 B
Line Pressure Solenoid Current (N-R Engagement)9x9 cells / 162 B
Transmission - Shift Schedule15 maps
MapShape / size
Shift Schedule Upshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Upshift Maximum5 cells / 10 B
Shift Schedule Upshift Minimum5 cells / 10 B
Shift Schedule Downshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Downshift Maximum5 cells / 10 B
Shift Schedule Downshift Minimum5 cells / 10 B
Shift Schedule Maximum Reduction (ATF Temp)7 cells / 14 B
Transmission - Shift Control5 maps
MapShape / size
I/C Solenoid Current17x8 cells / 272 B
H and LR/C Solenoid Current17x8 cells / 272 B
D/C Solenoid Current17x8 cells / 272 B
F/B Solenoid Current17x8 cells / 272 B
Fwd/B Solenoid Current17x8 cells / 272 B
Transmission - Lock-up13 maps
MapShape / size
Lock-up Engage (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Engage (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Engage (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Engage (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Engage (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Release (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Release (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Release (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Release (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Release (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Coast Minimum Speed (Pattern 2 Normal)5 cells / 10 B
Lock-up Coast Minimum Speed (Pattern 3 Manual Gate)5 cells / 10 B
Lock-up Solenoid Current16x6 cells / 192 B
YSD12WB0NEWWIPSubaru Exiga -JDM · 5EAT · SH705845 maps
Miscellaneous - Sensor Scalings1 map
MapShape / size
ATF Temperature Sensor Scaling16 cells / 32 B
Transmission - Line Pressure12 maps
MapShape / size
Line Pressure Minimum (ATF Temp)7 cells / 14 B
Line Pressure Base (1st)8x8 cells / 128 B
Line Pressure Base (2nd)8x8 cells / 128 B
Line Pressure Base (3rd)8x8 cells / 128 B
Line Pressure Base (4th)8x8 cells / 128 B
Line Pressure Base (5th)8x8 cells / 128 B
Line Pressure Base (Reverse)8x8 cells / 128 B
Line Pressure Minimum (Lock-up Pressure) A16 cells / 32 B
Line Pressure Minimum (Lock-up Pressure) B16 cells / 32 B
Line Pressure Solenoid Current9x9 cells / 162 B
Line Pressure Solenoid Current (Reverse and Alternate Gears)9x9 cells / 162 B
Line Pressure Solenoid Current (N-R Engagement)9x9 cells / 162 B
Transmission - Shift Schedule14 maps
MapShape / size
Shift Schedule Upshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Upshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Upshift Maximum5 cells / 10 B
Shift Schedule Upshift Minimum5 cells / 10 B
Shift Schedule Downshift (Pattern 2 Normal)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 2 Normal) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 3 Manual Gate) (Cold ATF)11x5 cells / 110 B
Shift Schedule Downshift (Pattern 8 High Temp)11x5 cells / 110 B
Shift Schedule Downshift Maximum5 cells / 10 B
Shift Schedule Downshift Minimum5 cells / 10 B
Transmission - Shift Control5 maps
MapShape / size
I/C Solenoid Current17x8 cells / 272 B
H and LR/C Solenoid Current17x8 cells / 272 B
D/C Solenoid Current17x8 cells / 272 B
F/B Solenoid Current17x8 cells / 272 B
Fwd/B Solenoid Current17x8 cells / 272 B
Transmission - Lock-up13 maps
MapShape / size
Lock-up Engage (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Engage (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Engage (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Engage (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Engage (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Release (Pattern 2 Normal)15x5 cells / 150 B
Lock-up Release (Pattern 3 Manual Gate)15x5 cells / 150 B
Lock-up Release (Pattern 5 Hot 1)15x5 cells / 150 B
Lock-up Release (Pattern 6 Hot 2)15x5 cells / 150 B
Lock-up Release (Pattern 7 Hot 3)15x5 cells / 150 B
Lock-up Coast Minimum Speed (Pattern 2 Normal)5 cells / 10 B
Lock-up Coast Minimum Speed (Pattern 3 Manual Gate)5 cells / 10 B
Lock-up Solenoid Current16x6 cells / 192 B

Request definition work